Chart Display

Y2K Compliant

TDU-850

TDU-1200-2

TDU-1200F

TDU-2000F

Paper Type

Direct thermal Direct thermal Direct thermal Direct thermal

Effective Printing width

8.5 in (21.6 cm) 11.84 in (30.07 cm) 11.85 in (30 cm) 20.16 in (51.2 cm)

Paper width

8.7 in ( 22.2 cm) 12.09 in (30.07 cm) 12.25 in (31.1 cm) 21.12 in (53.6 cm)

Paper length *

200 ft ( 61 m) 200 ft ( 61 m) 200 ft ( 61 m) 200 ft ( 61 m)

Dot density

203 dots/in
(8 dots/mm)
300 dots/in
(11.8 dots/mm)
300 dots/in
(11.8 dots/mm)
203 dots/in
(8 dots mm)

Dots per line

1728 3552 3552 4096

*length for plastic and transparency medium is 165 ft (150.3 m)

                      Resolution

 

TDU-850

TDU-1200-2

TDU1200F

TDU-2000F

Greyshades B/W,8,16,32,64,128,256 B/W,8,16,32,64,128,256 B/W,8,16,32* B/W,8,16,32,64*
Line Density 100 or 200 LPI 300 LPI 100,120,150,200,300 LPI 100,120,150,200,300 LPI
     

*32 and 64 limited to 0.625 sec/sweep

                      Electronic Design

 

TDU-850, TDU-1200-2

TDU-1200F, TDU-2000F

Input Signals                   (Data)
                                          (Control)
TTL compatible with 4.7K W pull up
TTL compatible with 4.7K W pull up
TTL compatible with 4.7K W pull up
TTL compatible, negative true, with 2.2K W pull up

Output Signals

TTL compatible TTL driven

Power

103.5 to 126 VAC, 47-63Hz, single phase 103.5 to 126 VAC, 47-63Hz, single phase

Power Requirements

200 W nominal 350 W maximum

                       Physical / Environmental

 

TDU-850

TDU-1200

TDU-1200F

TDU-2000F

Weight

25lbs 30 lbs. 45 lbs. (20.25kg) 60 lbs. (27.0kg)

Dimensions

7.58 in (19.25cm) H x
14.2 in (36cm) W x
17.5 in (45cm)D
7.78 in (19.76cm) H x
18.2 in (46.2cm) W x
17.5 in (45cm)D
8 in (20.3cm) H x
17.5 in (44.4cm) W x
20 in (50.8cm)D
8 in (20.3cm) H x
26.3 in (66.8cm) W x
20.5 in (52cm)D

Operating Temperature

0 to 50 C 0 to 50 C 0 to 50 C 0 to 50 C

Storage Temperature

-40 to +80 C -40 to +80 C -40 to +70 C -40 to +70 C

Humidity

95% non-condensing
(excluding paper)
95% non-condensing
(excluding paper)
95% non-condensing
(excluding paper)
95% non-condensing
(excluding paper)